Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1996 |
Principal Product | Specialty Chemicals |
NAICS | n/a |
SIC | 2861 - Gum And Wood Chemicals |
Sales | $50,000,000-$100,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 24,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $360,379 | 12,052,755 | kWh | $0.03 |
Electricity Demand | $187,190 | 21,868 | kW-months/year | $8.56 |
Electricity Fees | $35,621 | - | $ | - |
Natural Gas | $543,435 | 151,909 | MMBtu | $3.58 |
Other Energy | $1,045,416 | 384,345 | MMBtu | $2.72 |
TOTAL ENERGY COSTS | $2,820,041 | |||
RECOMMENDED SAVINGS* | $216,881 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $147,111 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Energy | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Energy | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $19,170 Cost: $116,000 |
$12,575 | 420,574 | $5,506 | 643 | $1,089 | - | - | - | - | - | - | - | - | - |
$12,575 420,574 kWh |
$5,506 643 kW-months/year |
$1,089 - $ |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $30,732 Cost: $2,000 |
- | - | - | - | - | - | $29,100 | 10,699 | - | - | $1,224 | 815,780 | $408 | - |
- - kWh |
- - kW-months/year |
- - $ |
$29,100 10,699 MMBtu |
- - MMBtu |
$1,224 815,780 Tgal |
$408 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $11,040 Cost: $8,800 |
$7,265 | 242,966 | $3,154 | 368 | $621 | - | - | - | - | - | - | - | - | - |
$7,265 242,966 kWh |
$3,154 368 kW-months/year |
$621 - $ |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $40,100 Cost: $30,000 |
- | - | - | - | - | - | $40,100 | 11,200 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$40,100 11,200 MMBtu |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $38,880 Cost: $60,000 |
- | - | - | - | - | - | $38,880 | 10,860 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$38,880 10,860 MMBtu |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $18,987 Cost: $400 |
- | - | - | - | - | - | - | - | $17,700 | 6,500 | $965 | 643,000 | $322 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$17,700 6,500 MMBtu |
$965 643,000 Tgal |
$322 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $680 Cost: $218 |
$360 | 12,016 | $291 | 34 | $29 | - | - | - | - | - | - | - | - | - |
$360 12,016 kWh |
$291 34 kW-months/year |
$29 - $ |
- - MMBtu |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $22,680 Cost: $2,500 |
- | - | - | - | - | - | - | - | $2,520 | 925 | $15,120 | 10,080,000 | $5,040 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,520 925 MMBtu |
$15,120 10,080,000 Tgal |
$5,040 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $34,612 Cost: $31,200 |
- | - | - | - | - | - | - | - | $21,800 | 8,000 | $9,609 | 6,406,000 | $3,203 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$21,800 8,000 MMBtu |
$9,609 6,406,000 Tgal |
$3,203 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $216,881 Cost: $251,118 |
$20,200 | 675,556 | $8,951 | 1,045 | $1,739 | - | $108,080 | 32,759 | $42,020 | 15,425 | $26,918 | 17,944,780 | $8,973 | - | $20,200 675,556 kWh |
$8,951 1,045 kW-months/year |
$1,739 - $ |
$108,080 32,759 MMBtu |
$42,020 15,425 MMBtu |
$26,918 17,944,780 Tgal |
$8,973 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $147,111 Cost: $66,100 |
- | - | - | - | - | - | $69,200 | 21,899 | $42,020 | 15,425 | $26,918 | 17,944,780 | $8,973 | - | - - kWh |
- - kW-months/year |
- - $ |
$69,200 21,899 MMBtu |
$42,020 15,425 MMBtu |
$26,918 17,944,780 Tgal |
$8,973 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Energy | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Energy | Water Disposal | Water Consumption |