IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

258

matching recommendations
Reset
SIC 287 Agricultural Chemicals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0394 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,467 $6,944 Implemented
OK0394 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,326 $6,750 Implemented
OK0394 # 03 Y:1993 03 1993 REDUCE EXCESSIVE BOILER BLOWDOWN $865 $1,270 Implemented
OK0394 # 04 Y:1993 04 1993 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $110 $296 Implemented
OK0394 # 05 Y:1993 05 1993 INSTALL SET-BACK TIMERS $627 $404 Not Implemented
OR0108 # 01 Y:1991 01 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $615 $0 Implemented
OR0108 # 02 Y:1991 02 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,129 $500 Implemented
OR0108 # 03 Y:1991 03 1991 INSULATE BARE EQUIPMENT $2,482 $4,030 Implemented
OR0108 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $407 $0 Implemented
OR0108 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21 $60 Implemented
OK0327 # 01 Y:1990 01 1990 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $10,526 $2,150 Implemented
OK0327 # 02 Y:1990 02 1990 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,335 $5,076 Not Implemented
OK0327 # 03 Y:1990 03 1990 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $28,082 $13,087 Implemented
OK0327 # 04 Y:1990 04 1990 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $7,590 $4,484 Not Implemented
OK0327 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,932 $3,700 Implemented
OK0327 # 06 Y:1990 06 1990 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $63,353 $244,600 Not Implemented
OK0327 # 07 Y:1990 07 1990 INSTALL SET-BACK TIMERS $1,894 $650 Implemented
OK0327 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,670 $17,150 Implemented
OK0327 # 09 Y:1990 09 1990 INSTALL TIMERS AND/OR THERMOSTATS $232 $440 Not Implemented
OK0327 # 10 Y:1990 10 1990 INSULATE BARE EQUIPMENT $7,033 $27,000 Not Implemented
AM0032 # 01 Y:1988 01 1988 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $3,735 $6,790 Not Implemented
AM0032 # 02 Y:1988 02 1988 COMBINE UTILITY METERS $1,450 $2,000 Not Implemented
AM0032 # 03 Y:1988 03 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $115 $94 Not Implemented
AM0032 # 04 Y:1988 04 1988 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,193 $504 Not Implemented
AM0032 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,096 $0 Implemented