Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

24

matching recommendations
Reset
SIC 2893 Printing Ink
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0229 # 08 Y:1998 08 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $720 $2,080 Not Implemented
MO0229 # 07 Y:1998 07 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,484 $6,161 Implemented
MO0229 # 06 Y:1998 06 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,496 $52 Not Implemented
MO0229 # 05 Y:1998 05 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,899 $40 Implemented
MO0229 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $708 $1,568 Implemented
MO0229 # 03 Y:1998 03 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,548 $7,376 Implemented
MO0229 # 02 Y:1998 02 1998 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $11,035 $3,700 Not Implemented
MO0229 # 01 Y:1998 01 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,111,888 $0 Not Implemented
KU0237 # 07 Y:1987 07 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $390 $40 Not Implemented
KU0237 # 10 Y:1987 10 1987 INSTALL TIMERS AND/OR THERMOSTATS $3,307 $157 Implemented
KU0237 # 09 Y:1987 09 1987 IMPROVE LUBRICATION PRACTICES $597 $0 Not Implemented
KU0237 # 08 Y:1987 08 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $519 $0 Implemented
KU0237 # 06 Y:1987 06 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,203 $200 Implemented
KU0237 # 05 Y:1987 05 1987 INSTALL AUTOMATIC STACK DAMPER $313 $250 Not Implemented
KU0237 # 04 Y:1987 04 1987 RECOVER WASTE HEAT FROM EQUIPMENT $407 $250 Implemented
KU0237 # 03 Y:1987 03 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,921 $2,000 Not Implemented
KU0237 # 02 Y:1987 02 1987 INSTALL AUTOMATIC STACK DAMPER $399 $250 Not Implemented
KU0237 # 01 Y:1987 01 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,838 $600 Not Implemented
KU0184 # 01 Y:1986 01 1986 IMPROVE LUBRICATION PRACTICES $327 $0 Not Implemented
KU0184 # 06 Y:1986 06 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $265 $0 Not Implemented
KU0184 # 05 Y:1986 05 1986 USE OPTIMUM TEMPERATURE $545 $50 Not Implemented
KU0184 # 04 Y:1986 04 1986 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $495 $72 Not Implemented
KU0184 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,331 $0 Not Implemented
KU0184 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $989 $1,087 Not Implemented