Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

694

matching recommendations
Reset
SIC 29 Petroleum And Coal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0010 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,459 $1,483 Implemented
AR0010 # 02 Y:1993 02 1993 REPAIR AND ELIMINATE STEAM LEAKS $8,251 $1,400 Implemented
AR0010 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,539 $16,518 Implemented
AR0010 # 05 Y:1993 05 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,412 $30 Implemented
CO0280 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,120 $12,600 Implemented
CO0280 # 02 Y:1993 02 1993 INSULATE BARE EQUIPMENT $3,150 $1,730 Implemented
CO0280 # 06 Y:1993 06 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $360 $100 Implemented
UD0399 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $11,080 $23,750 Implemented
UD0399 # 03 Y:1993 03 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $4,749 $23,750 Implemented
SD0052 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $165 $222 Implemented
SD0052 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,255 $4,329 Implemented
SD0052 # 03 Y:1993 03 1993 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $312 $658 Implemented
SD0052 # 04 Y:1993 04 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $1,571 $654 Implemented
SD0052 # 05 Y:1993 05 1993 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $9,280 $2,450 Implemented
SD0052 # 06 Y:1993 06 1993 REPAIR OR REPLACE STEAM TRAPS $14,542 $6,550 Implemented
SD0052 # 07 Y:1993 07 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,035 $40 Implemented
SD0052 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $434 $0 Implemented
GT0472 # 01 Y:1992 01 1992 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $58,750 $22,000 Implemented
GT0472 # 02 Y:1992 02 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $53,900 $56,000 Implemented
GT0472 # 03 Y:1992 03 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,247 $500 Implemented
GT0472 # 04 Y:1992 04 1992 INSULATE BARE EQUIPMENT $35,964 $13,262 Implemented
GT0472 # 05 Y:1992 05 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,747 $23,600 Implemented
GT0472 # 06 Y:1992 06 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $538 $0 Implemented
GT0472 # 07 Y:1992 07 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $102 $1,210 Implemented
CO0233 # 01 Y:1992 01 1992 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,100 $250 Implemented