Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 299 | Misc. Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3008 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,619 | $1,500 | Not Implemented |
UA3008 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $6,109 | $337 | Implemented |
UA3008 # 02 Y:2010 | 02 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,598 | $17,500 | Implemented |
UA3008 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,485 | $640 | Not Implemented |
UA3008 # 03 Y:2010 | 03 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,470 | $2,149 | Implemented |
UA3008 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $12,090 | $20,526 | Not Implemented |
UA3008 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,004 | $16,161 | Not Implemented |
UA3008 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $497 | $340 | Not Implemented |
DL0056 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $184,560 | $1,200,000 | Implemented |
DL0056 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,100 | $58,000 | Not Implemented |
DL0056 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,000 | $94,500 | Not Implemented |
DL0056 # 07 Y:2010 | 07 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,100 | $100 | Not Implemented |
DL0056 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM TEMPERATURE | $7,644 | $100 | Implemented |
DL0056 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,000 | $300 | Implemented |
DL0056 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $45,700 | $7,900 | Not Implemented |
DL0056 # 03 Y:2010 | 03 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $42,720 | $1,940 | Not Implemented |
DL0056 # 02 Y:2010 | 02 | 2010 | KEEP EQUIPMENT CLEAN | $162,929 | $102,000 | Not Implemented |
DL0045 # 09 Y:2010 | 09 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,229 | $100,000 | Implemented |
DL0045 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,605 | $35,400 | Not Implemented |
DL0045 # 07 Y:2010 | 07 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $705 | $680 | Not Implemented |
DL0045 # 06 Y:2010 | 06 | 2010 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $3,560 | $2,000 | Implemented |
DL0045 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $894 | $455 | Not Implemented |
DL0045 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $647 | $0 | Not Implemented |
DL0045 # 03 Y:2010 | 03 | 2010 | REDUCE VENTILATION AIR | $3,013 | $0 | Not Implemented |
DL0045 # 02 Y:2010 | 02 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,204 | $0 | Implemented |