Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2010 |
Principal Product | Lubricants |
NAICS | 324191 - Petroleum Lubricating Oil and Grease Manufacturing |
SIC | 2992 - Lubricating Oils And Greases |
Sales | <$500,000 |
# of Employees | 36 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 21,000 Thousand Gallons |
Production Hrs. Annual | 4,080 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $221,885 | 1,549,900 | kWh | $0.14 |
Electricity Demand | $18,625 | 391 | kW-months/year | $47.63 |
Electricity Fees | $19,226 | - | $ | - |
Natural Gas | $55,791 | 4,294 | MMBtu | $12.99 |
Fuel Oil #2 | $63,822 | 4,203 | MMBtu | $15.18 |
TOTAL ENERGY COSTS | $379,349 | |||
RECOMMENDED SAVINGS* | $56,668 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,993 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Fuel Oil #2 | Ancillary Material Cost | Water Consumption | Electricity Usage | Natural Gas | Fuel Oil #2 | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $7,811 Cost: - |
$1,420 | 8,455 | $6,391 | 492 | - | - | - | - | - | - |
$1,420 8,455 kWh |
$6,391 492 MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $6,204 Cost: - |
$1,008 | 6,000 | $5,196 | 400 | - | - | - | - | - | - |
$1,008 6,000 kWh |
$5,196 400 MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7314 REDUCE VENTILATION AIR |
Savings: $3,013 Cost: - |
$740 | 4,402 | $2,273 | 175 | - | - | - | - | - | - |
$740 4,402 kWh |
$2,273 175 MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $647 Cost: - |
$647 | 3,804 | - | - | - | - | - | - | - | - |
$647 3,804 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $894 Cost: $455 |
$894 | 5,258 | - | - | - | - | - | - | - | - |
$894 5,258 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $3,560 Cost: $2,000 |
- | - | - | - | - | - | $3,560 | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$3,560 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $705 Cost: $680 |
$705 | 4,200 | - | - | - | - | - | - | - | - |
$705 4,200 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,605 Cost: $35,400 |
$13,605 | 80,988 | - | - | - | - | - | - | - | - |
$13,605 80,988 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $20,229 Cost: $100,000 |
$1,100 | 6,630 | - | - | $18,200 | 1,200 | - | - | $929 | - |
$1,100 6,630 kWh |
- - MMBtu |
$18,200 1,200 MMBtu |
- - $ |
$929 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,668 Cost: $138,535 |
$20,119 | 119,737 | $13,860 | 1,067 | $18,200 | 1,200 | $3,560 | - | $929 | - | $20,119 119,737 kWh |
$13,860 1,067 MMBtu |
$18,200 1,200 MMBtu |
$3,560 - $ |
$929 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,993 Cost: $102,000 |
$2,108 | 12,630 | $5,196 | 400 | $18,200 | 1,200 | $3,560 | - | $929 | - | $2,108 12,630 kWh |
$5,196 400 MMBtu |
$18,200 1,200 MMBtu |
$3,560 - $ |
$929 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Fuel Oil #2 | Ancillary Material Cost | Water Consumption | Electricity Usage | Natural Gas | Fuel Oil #2 | Ancillary Material Cost | Water Consumption |