Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,816
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0247 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $490 | $780 | Implemented |
CO0247 # 08 Y:1992 | 08 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $590 | $1,350 | Implemented |
CO0247 # 09 Y:1992 | 09 | 1992 | UPGRADE CONTROLS ON COMPRESSORS | $5,970 | $12,000 | Implemented |
CO0247 # 10 Y:1992 | 10 | 1992 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $230 | $530 | Implemented |
CO0247 # 11 Y:1992 | 11 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,470 | $6,280 | Implemented |
CO0247 # 12 Y:1992 | 12 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,050 | $30,250 | Implemented |
UD0376 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,478 | $0 | Implemented |
UD0376 # 02 Y:1992 | 02 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,160 | $0 | Implemented |
UD0376 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $556 | $0 | Implemented |
OR0148 # 01 Y:1992 | 01 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $942 | $0 | Implemented |
OR0148 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $86 | $0 | Implemented |
OR0148 # 04 Y:1992 | 04 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,487 | $2,700 | Implemented |
OR0148 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $934 | $1,000 | Implemented |
OR0148 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $544 | $228 | Implemented |
MA0245 # 02 Y:1992 | 02 | 1992 | REDESIGN PROCESS | $4,412 | $1,554 | Implemented |
MA0245 # 03 Y:1992 | 03 | 1992 | RECOVER AND REUSE COOLING WATER | $2,833 | $5,040 | Implemented |
MA0245 # 04 Y:1992 | 04 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,237 | $0 | Implemented |
MA0246 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $1,358 | $2,672 | Implemented |
MA0246 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $526 | $0 | Implemented |
MA0246 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $443 | $386 | Implemented |
MA0246 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $100 | $85 | Implemented |
OK0384 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,774 | $0 | Implemented |
OK0384 # 06 Y:1992 | 06 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $11,847 | $16,034 | Implemented |
UD0372 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,610 | $0 | Implemented |
UD0372 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $305 | $6,008 | Implemented |