Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0039 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $704 | $3,010 | Not Implemented |
WM0039 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $330 | $208 | Not Implemented |
WM0039 # 07 Y:2014 | 07 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,724 | $4,550 | Not Implemented |
WM0039 # 08 Y:2014 | 08 | 2014 | USE SYNTHETIC LUBRICANT | $26,656 | $5,209 | Implemented |
SD0478 # 01 Y:2014 | 01 | 2014 | REDUCE SCRAP PRODUCTION | $30,811 | $12,465 | Implemented |
SD0478 # 02 Y:2014 | 02 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,342 | $32,990 | Not Implemented |
SD0478 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,128 | $500 | Implemented |
SD0478 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $2,630 | $2,535 | Implemented |
SD0478 # 05 Y:2014 | 05 | 2014 | USE PHOTOCELL CONTROLS | $2,220 | $4,625 | Implemented |
SU0358 # 01 Y:2014 | 01 | 2014 | ELIMINATE/REDUCE AN OPERATION | $347 | $0 | Implemented |
SU0358 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,384 | $3,267 | Not Implemented |
SU0358 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $797 | $590 | Implemented |
SU0358 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $164 | $114 | Implemented |
SU0358 # 05 Y:2014 | 05 | 2014 | ELIMINATE/REDUCE AN OPERATION | $3,205 | $3,000 | Not Implemented |
SU0358 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $688 | $2,000 | Not Implemented |
SU0358 # 07 Y:2014 | 07 | 2014 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $197 | $568 | Not Implemented |
UD0896 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $74 | $0 | Implemented |
UD0896 # 02 Y:2014 | 02 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $31,308 | $10,500 | Not Implemented |
UD0896 # 03 Y:2014 | 03 | 2014 | MINIMIZE WATER USAGE | $7,067 | $8,000 | Not Implemented |
UD0896 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $500 | Not Implemented |
UD0896 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22 | $0 | Not Implemented |
UD0896 # 06 Y:2014 | 06 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $8,000 | Not Implemented |
UD0896 # 07 Y:2014 | 07 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,035 | $1,211 | Not Implemented |
UD0896 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $794 | $1,000 | Not Implemented |
UD0895 # 01 Y:2014 | 01 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $72,083 | $0 | Implemented |