399
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0012 # 07 Y:1994 | 07 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,836 | $0 | Implemented |
ND0043 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,311 | $948 | Implemented |
ND0043 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,269 | $300 | Implemented |
ND0043 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $212 | $3,350 | Implemented |
ND0043 # 04 Y:1992 | 04 | 1992 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $249 | $120 | Not Implemented |
ND0043 # 05 Y:1992 | 05 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $64 | $160 | Implemented |
ND0035 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,788 | $7,000 | Implemented |
ND0035 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $474 | $654 | Not Implemented |
ND0035 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $517 | $200 | Implemented |
ND0035 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $758 | $500 | Implemented |
ND0029 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,484 | $6,140 | Implemented |
ND0029 # 02 Y:1992 | 02 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,172 | $400 | Implemented |
ND0029 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $124 | $528 | Not Implemented |
ND0029 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50 | $100 | Not Implemented |
TS0033 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $13,881 | $2,730 | Not Implemented |
TS0033 # 02 Y:1986 | 02 | 1986 | USE OPTIMUM THICKNESS INSULATION | $1,345 | $2,730 | Not Implemented |
TS0033 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,996 | $178 | Not Implemented |
TS0033 # 04 Y:1986 | 04 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,601 | $0 | Not Implemented |
TS0033 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,451 | $1,000 | Not Implemented |
TS0033 # 06 Y:1986 | 06 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $922 | $1,300 | Not Implemented |
TS0026 # 01 Y:1985 | 01 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,637 | $3,240 | Not Implemented |
TS0026 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $325 | $460 | Not Implemented |
TS0026 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,640 | $503 | Not Implemented |
TS0026 # 04 Y:1985 | 04 | 1985 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,372 | $400 | Not Implemented |