IAC logo
IAC Assessment: UM0012
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UM0012
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 1994
Principal Product Plastic Bags and Films
NAICS n/a
SIC 3081 - Unsupported Plastics Film & Sheet
Sales $5,000,000-$10,000,000
# of Employees 45
Plant Area (Sq.Ft.) 56,000
Annual Production 6,000,000 Pounds
Production Hrs. Annual 6,000
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $122,240 2,068,875 kWh $0.06
Natural Gas $15,598 3,820 MMBtu $4.08
TOTAL ENERGY COSTS $137,838
RECOMMENDED SAVINGS* $12,451 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,406
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,061
Cost:
$2,890
$2,061 34,877 - - $2,061
34,877
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,236
Cost:
$4,084
$1,236 21,102 - - $1,236
21,102
kWh
-
-
MMBtu
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$2,542
Cost:
$6,800
- - $2,542 623 -
-
kWh
$2,542
623
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,273
Cost:
$1,600
$1,273 21,688 - - $1,273
21,688
kWh
-
-
MMBtu
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$2,888
Cost:
$2,000
- - $2,888 708 -
-
kWh
$2,888
708
MMBtu
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$615
Cost:
$500
$807 13,775 $(-192) (-59) $807
13,775
kWh
$(-192)
(-59)
MMBtu
07: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,836
Cost:
-
- - $1,836 450 -
-
kWh
$1,836
450
MMBtu
TOTAL RECOMMENDED Savings:
$12,451
Cost:
$17,874
$5,377 91,442 $7,074 1,722 $5,377
91,442
kWh
$7,074
1,722
MMBtu
TOTAL IMPLEMENTED Savings:
$6,406
Cost:
$8,574
$4,570 77,667 $1,836 450 $4,570
77,667
kWh
$1,836
450
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas