IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,163

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0099 # 07 Y:2005 07 2005 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,010 $0 Not Implemented
TA0099 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $870 $325 Not Implemented
AM0494 # 01 Y:2005 01 2005 REPAIR AND ELIMINATE STEAM LEAKS $14,700 $5,000 Implemented
AM0494 # 02 Y:2005 02 2005 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $5,880 $540 Implemented
AM0494 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,400 $500 Implemented
AM0494 # 04 Y:2005 04 2005 REPAIR OR REPLACE STEAM TRAPS $4,450 $800 Implemented
AM0494 # 05 Y:2005 05 2005 OPTIMIZE PLANT POWER FACTOR $3,870 $9,160 Implemented
AM0494 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,440 $760 Not Implemented
AM0494 # 07 Y:2005 07 2005 INSULATE BARE EQUIPMENT $1,370 $795 Not Implemented
AM0494 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,330 $12 Implemented
AM0494 # 09 Y:2005 09 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $870 $0 Implemented
AM0494 # 10 Y:2005 10 2005 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $770 $660 Implemented
AM0494 # 11 Y:2005 11 2005 USE SYNTHETIC LUBRICANT $570 $0 Not Implemented
AM0494 # 12 Y:2005 12 2005 ELIMINATE LEAKS IN WATER LINES AND VALVES $230 $200 Implemented
AM0491 # 01 Y:2005 01 2005 OPTIMIZE PLANT POWER FACTOR $20,300 $56,420 Implemented
AM0491 # 02 Y:2005 02 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $8,990 $684 Implemented
AM0491 # 03 Y:2005 03 2005 USE SYNTHETIC LUBRICANT $2,720 $0 Implemented
AM0491 # 04 Y:2005 04 2005 USE PHOTOCELL CONTROLS $380 $0 Implemented
TA0083 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $42,038 $0 Not Implemented
TA0083 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $25,800 $2,070 Not Implemented
TA0083 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $25,680 $25 Not Implemented
TA0083 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,500 $370 Not Implemented
TA0083 # 05 Y:2004 05 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $5,350 $0 Not Implemented
TA0083 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $4,670 $910 Not Implemented
TA0083 # 07 Y:2004 07 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $3,263 $0 Not Implemented