Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
353
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0276 # 07 Y:2008 | 07 | 2008 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,838 | $3,600 | Not Implemented |
LE0276 # 06 Y:2008 | 06 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,749 | $16,800 | Not Implemented |
LE0276 # 05 Y:2008 | 05 | 2008 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $15,550 | $500 | Not Implemented |
LE0276 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,230 | $16,000 | Implemented |
LE0276 # 03 Y:2008 | 03 | 2008 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $38,127 | $30,600 | Not Implemented |
LE0276 # 02 Y:2008 | 02 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $55,360 | $30,000 | Not Implemented |
LE0276 # 01 Y:2008 | 01 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $144,000 | $92,000 | Implemented |
LE0155 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,520 | $0 | Implemented |
LE0155 # 10 Y:2003 | 10 | 2003 | USE SYNTHETIC LUBRICANT | $251 | $200 | Implemented |
LE0155 # 09 Y:2003 | 09 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $273 | $0 | Implemented |
LE0155 # 08 Y:2003 | 08 | 2003 | PAY UTILITY BILLS ON TIME | $4,771 | $0 | Implemented |
LE0155 # 07 Y:2003 | 07 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $795 | $500 | Not Implemented |
LE0155 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $588 | $925 | Not Implemented |
LE0155 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,288 | $300 | Implemented |
LE0155 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,873 | $0 | Not Implemented |
LE0155 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,269 | $2,500 | Not Implemented |
LE0155 # 01 Y:2003 | 01 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $947 | $0 | Implemented |
HO0225 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,603 | $15 | Not Implemented |
HO0225 # 08 Y:2000 | 08 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,294 | $80 | Not Implemented |
HO0225 # 06 Y:2000 | 06 | 2000 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,819 | $1,860 | Not Implemented |
HO0225 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,277 | $800 | Not Implemented |
HO0225 # 02 Y:2000 | 02 | 2000 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $140,732 | $210,000 | Not Implemented |
HO0225 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $999 | $1,969 | Implemented |
HO0225 # 04 Y:2000 | 04 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,147 | $7,000 | Not Implemented |
HO0225 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,058 | $800 | Not Implemented |