Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0391 # 05 Y:1993 | 05 | 1993 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $527 | $550 | Implemented |
UD0391 # 06 Y:1993 | 06 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $861 | $1,214 | Not Implemented |
OK0390 # 01 Y:1992 | 01 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,672 | $0 | Implemented |
OK0390 # 02 Y:1992 | 02 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $703 | $8,556 | Not Implemented |
OK0390 # 03 Y:1992 | 03 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,340 | $0 | Not Implemented |
OK0390 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $733 | $447 | Implemented |
OK0390 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $88 | $964 | Implemented |
OK0390 # 06 Y:1992 | 06 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $772 | Implemented |
OK0390 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $302 | $302 | Implemented |
UD0384 # 01 Y:1992 | 01 | 1992 | OPTIMIZE PLANT POWER FACTOR | $31,568 | $41,000 | Not Implemented |
UD0384 # 02 Y:1992 | 02 | 1992 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $15,864 | $22,000 | Not Implemented |
UD0384 # 03 Y:1992 | 03 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $11,343 | $3,000 | Implemented |
UD0384 # 04 Y:1992 | 04 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,400 | $800 | Not Implemented |
UD0384 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,257 | $23,650 | Not Implemented |
GT0479 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,282 | $18,910 | Not Implemented |
GT0479 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,180 | $1,480 | Not Implemented |
GT0479 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $16,146 | $20,488 | Not Implemented |
GT0479 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,378 | $28,850 | Not Implemented |
GT0479 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,086 | $450 | Not Implemented |
GT0479 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,000 | $450 | Not Implemented |
GT0479 # 07 Y:1992 | 07 | 1992 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,392 | $1,250 | Not Implemented |
GT0479 # 08 Y:1992 | 08 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $88,450 | $133,000 | Not Implemented |
SD0033 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,066 | $12,195 | Not Implemented |
SD0033 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,962 | $20 | Not Implemented |
SD0033 # 03 Y:1992 | 03 | 1992 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $11,846 | $4,000 | Not Implemented |