Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,096
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0358 # 08 Y:1988 | 08 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,270 | $3,100 | Implemented |
LT0134 # 01 Y:1988 | 01 | 1988 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $124 | $200 | Not Implemented |
LT0134 # 02 Y:1988 | 02 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,336 | $0 | Implemented |
LT0134 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $564 | $0 | Implemented |
LT0134 # 04 Y:1988 | 04 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $608 | $1,188 | Not Implemented |
LT0134 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,164 | $0 | Implemented |
LT0134 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $109 | Not Implemented |
LT0134 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $171 | $372 | Implemented |
LT0132 # 01 Y:1988 | 01 | 1988 | INSULATE BARE EQUIPMENT | $1,820 | $1,967 | Implemented |
LT0132 # 02 Y:1988 | 02 | 1988 | REDESIGN PROCESS | $23,180 | $3,057 | Not Implemented |
LT0132 # 03 Y:1988 | 03 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $352 | $855 | Not Implemented |
LT0132 # 04 Y:1988 | 04 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $256 | $300 | Implemented |
LT0132 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50 | $120 | Not Implemented |
LT0132 # 06 Y:1988 | 06 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $1,500 | $150 | Not Implemented |
LT0132 # 07 Y:1988 | 07 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,000 | $3,680 | Not Implemented |
KU0269 # 01 Y:1988 | 01 | 1988 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $17,859 | $10,000 | Not Implemented |
KU0269 # 02 Y:1988 | 02 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,858 | $0 | Implemented |
KU0269 # 03 Y:1988 | 03 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $5,967 | $5,600 | Implemented |
KU0269 # 04 Y:1988 | 04 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $243 | $450 | Not Implemented |
KU0269 # 05 Y:1988 | 05 | 1988 | RECOVER AND REUSE COOLING WATER | $728 | $0 | Not Implemented |
KU0269 # 06 Y:1988 | 06 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $166 | $0 | Implemented |
MA0128 # 01 Y:1988 | 01 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,672 | $16,500 | Implemented |
MA0128 # 02 Y:1988 | 02 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,463 | $0 | Not Implemented |
MA0128 # 03 Y:1988 | 03 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,562 | $0 | Implemented |
MA0128 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $216 | $69 | Implemented |