Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,096
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0205 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,886 | $5,000 | Implemented |
UD0205 # 03 Y:1986 | 03 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,480 | $52,200 | Implemented |
UD0205 # 04 Y:1986 | 04 | 1986 | INSTALL STORM WINDOWS AND DOORS | $6,617 | $6,040 | Not Implemented |
UD0205 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,237 | $12,000 | Implemented |
UD0205 # 06 Y:1986 | 06 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,622 | $11,000 | Implemented |
MA0066 # 01 Y:1986 | 01 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,416 | $200 | Not Implemented |
MA0066 # 02 Y:1986 | 02 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $248 | $200 | Implemented |
MA0066 # 03 Y:1986 | 03 | 1986 | INSTALL STORM WINDOWS AND DOORS | $474 | $1,000 | Implemented |
MA0066 # 04 Y:1986 | 04 | 1986 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,424 | $0 | Implemented |
OK0202 # 01 Y:1986 | 01 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $3,870 | $6,000 | Not Implemented |
OK0202 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $209 | $868 | Implemented |
OK0202 # 03 Y:1986 | 03 | 1986 | INSULATE BARE EQUIPMENT | $45 | $138 | Implemented |
OK0202 # 04 Y:1986 | 04 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,466 | $45 | Implemented |
OK0202 # 05 Y:1986 | 05 | 1986 | INSTALL SET-BACK TIMERS | $892 | $860 | Not Implemented |
AT0040 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,491 | $971 | Not Implemented |
AT0040 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $399 | $200 | Not Implemented |
AT0040 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,093 | $57 | Implemented |
AT0040 # 04 Y:1986 | 04 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $24,638 | $30,000 | Not Implemented |
MA0058 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,060 | $90 | Implemented |
MA0058 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $3,740 | $5,760 | Implemented |
MA0058 # 03 Y:1986 | 03 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,028 | $0 | Implemented |
LT0055 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $287 | $270 | Implemented |
LT0055 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $219 | $360 | Not Implemented |
LT0055 # 03 Y:1986 | 03 | 1986 | USE OPTIMUM THICKNESS INSULATION | $4,130 | $5,659 | Implemented |
LT0055 # 04 Y:1986 | 04 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,226 | $1,220 | Not Implemented |