Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
557
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0373 # 09 Y:2014 | 09 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $681 | $1,400 | Not Implemented |
LE0373 # 10 Y:2014 | 10 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,395 | $4,250 | Not Implemented |
LE0372 # 01 Y:2014 | 01 | 2014 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $465 | $30 | Not Implemented |
LE0372 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $857 | $134 | Not Implemented |
LE0372 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,294 | $1,500 | Implemented |
LE0372 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,320 | $520 | Not Implemented |
LE0372 # 05 Y:2014 | 05 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,601 | $1,870 | Not Implemented |
LE0372 # 06 Y:2014 | 06 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,173 | $5,400 | Not Implemented |
LE0372 # 07 Y:2014 | 07 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,519 | $6,700 | Not Implemented |
LE0372 # 08 Y:2014 | 08 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $645 | $711 | Implemented |
LE0372 # 09 Y:2014 | 09 | 2014 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $24,930 | $41,000 | Not Implemented |
LE0372 # 10 Y:2014 | 10 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,402 | $13,500 | Not Implemented |
LE0372 # 11 Y:2014 | 11 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $9,045 | $16,500 | Implemented |
LE0372 # 12 Y:2014 | 12 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $96 | $210 | Not Implemented |
LE0372 # 13 Y:2014 | 13 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,361 | $7,792 | Not Implemented |
LE0372 # 14 Y:2014 | 14 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,482 | $4,118 | Not Implemented |
LE0372 # 15 Y:2014 | 15 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,408 | $64,631 | Not Implemented |
DL0108 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39,709 | $0 | Implemented |
DL0108 # 02 Y:2013 | 02 | 2013 | ADJUST VENTS TO MINIMIZE ENERGY USE | $3,279 | $0 | Not Implemented |
DL0108 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,367 | $0 | Implemented |
DL0108 # 04 Y:2013 | 04 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,687 | $270 | Implemented |
DL0108 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $200 | Implemented |
DL0108 # 06 Y:2013 | 06 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,400 | $400 | Not Implemented |
DL0108 # 07 Y:2013 | 07 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $543 | $0 | Implemented |
DL0108 # 08 Y:2013 | 08 | 2013 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $186,000 | $500,000 | Not Implemented |