Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0192 # 11 Y:2000 | 11 | 2000 | PAY UTILITY BILLS ON TIME | $482 | $0 | Implemented |
WV0192 # 10 Y:2000 | 10 | 2000 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $85,619 | $56,000 | Not Implemented |
WV0192 # 09 Y:2000 | 09 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $8,340 | $0 | Not Implemented |
WV0192 # 08 Y:2000 | 08 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $5,850 | $65 | Not Implemented |
WV0192 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $631 | $475 | Implemented |
WV0192 # 06 Y:2000 | 06 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,848 | $200 | Not Implemented |
WV0192 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,440 | $20 | Implemented |
WV0192 # 04 Y:2000 | 04 | 2000 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $414 | $65 | Implemented |
WV0192 # 03 Y:2000 | 03 | 2000 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,441 | $800 | Implemented |
WV0192 # 02 Y:2000 | 02 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $7,224 | $1,645 | Not Implemented |
WV0192 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $922 | $40 | Implemented |
WV0189 # 12 Y:2000 | 12 | 2000 | INSTALL BACK-UP EQUIPMENT | $13,104 | $375 | Implemented |
WV0189 # 01 Y:2000 | 01 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $876 | $1,936 | Implemented |
WV0189 # 11 Y:2000 | 11 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $887 | $5,000 | Not Implemented |
WV0189 # 10 Y:2000 | 10 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $120 | $25 | Not Implemented |
WV0189 # 09 Y:2000 | 09 | 2000 | INSTALL SKYLIGHTS | $2,123 | $2,436 | Implemented |
WV0189 # 08 Y:2000 | 08 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,653 | $10,800 | Implemented |
WV0189 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,574 | $32 | Not Implemented |
WV0189 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $675 | $275 | Implemented |
WV0189 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $498 | $325 | Implemented |
WV0189 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $338 | $120 | Not Implemented |
WV0189 # 03 Y:2000 | 03 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $728 | $780 | Not Implemented |
WV0189 # 02 Y:2000 | 02 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,448 | $0 | Not Implemented |