Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
242
matching recommendationsSIC | 301 | Tires And Inner Tubes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0535 # 02 Y:1994 | 02 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,687 | $660 | Implemented |
TN0535 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,456 | $0 | Implemented |
TN0535 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,556 | $1,248 | Implemented |
TN0535 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,943 | $0 | Not Implemented |
TN0535 # 06 Y:1994 | 06 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,794 | $0 | Implemented |
TN0535 # 07 Y:1994 | 07 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,256 | $0 | Implemented |
TN0535 # 08 Y:1994 | 08 | 1994 | USE SYNTHETIC LUBRICANT | $1,121 | $0 | Implemented |
TN0535 # 09 Y:1994 | 09 | 1994 | INSULATE BARE EQUIPMENT | $315 | $145 | Implemented |
TN0535 # 10 Y:1994 | 10 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $987 | $3,000 | Not Implemented |
TN0535 # 11 Y:1994 | 11 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $209 | $179 | Implemented |
TN0535 # 12 Y:1994 | 12 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $154,581 | $34,400 | Not Implemented |
TN0535 # 13 Y:1994 | 13 | 1994 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $19,814 | $15,400 | Not Implemented |
TN0535 # 14 Y:1994 | 14 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $13,077 | $10,000 | Not Implemented |
TN0535 # 15 Y:1994 | 15 | 1994 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,451 | $0 | Implemented |
AR0019 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,832 | $450 | Implemented |
AR0019 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,270 | $1,996 | Implemented |
AR0019 # 03 Y:1994 | 03 | 1994 | REPAIR AND ELIMINATE STEAM LEAKS | $8,858 | $2,200 | Implemented |
AR0019 # 04 Y:1994 | 04 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $15,987 | $1,177 | Implemented |
AR0019 # 05 Y:1994 | 05 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $29,704 | $0 | Not Implemented |
AR0019 # 06 Y:1994 | 06 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $22,243 | $47,000 | Not Implemented |
SF0015 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,029 | $9,608 | Implemented |
SF0015 # 02 Y:1993 | 02 | 1993 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $8,821 | $20,000 | Not Implemented |
SF0015 # 03 Y:1993 | 03 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,452 | $1,650 | Implemented |
SF0015 # 04 Y:1993 | 04 | 1993 | USE PHOTOCELL CONTROLS | $2,119 | $1,068 | Not Implemented |
SF0015 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $1,767 | $1,062 | Implemented |