Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsSIC | 302 | Rubber And Plastics Footwear |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0486 # 01 Y:1997 | 01 | 1997 | INSULATE BARE EQUIPMENT | $12,940 | $11,560 | Implemented |
KU0486 # 09 Y:1997 | 09 | 1997 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $590 | $170 | Not Implemented |
KU0486 # 08 Y:1997 | 08 | 1997 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $3,180 | $0 | Not Implemented |
KU0486 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $1,560 | $1,150 | Implemented |
KU0486 # 06 Y:1997 | 06 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,020 | $2,980 | Implemented |
KU0486 # 05 Y:1997 | 05 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,990 | $10,200 | Implemented |
KU0486 # 04 Y:1997 | 04 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,080 | $9,220 | Not Implemented |
KU0486 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,010 | $790 | Implemented |
KU0486 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,710 | $13,580 | Implemented |
MO0083 # 01 Y:1993 | 01 | 1993 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $5,261 | $13,500 | Not Implemented |
MO0083 # 08 Y:1993 | 08 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $186 | $401 | Not Implemented |
MO0083 # 07 Y:1993 | 07 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,098 | $2,381 | Not Implemented |
MO0083 # 06 Y:1993 | 06 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,216 | $3,873 | Not Implemented |
MO0083 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,699 | $2,195 | Implemented |
MO0083 # 04 Y:1993 | 04 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $1,343 | $2,703 | Not Implemented |
MO0083 # 03 Y:1993 | 03 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $4,773 | $75 | Implemented |
MO0083 # 02 Y:1993 | 02 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,998 | $336 | Not Implemented |