Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 305 | Hose & Belting & Gaskets & Packing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0501 # 02 Y:2013 | 02 | 2013 | ISOLATE HOT OR COLD EQUIPMENT | $705 | $840 | Not Implemented |
IA0501 # 01 Y:2013 | 01 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $4,234 | $2,800 | Implemented |
IA0501 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,349 | $1,200 | Not Implemented |
IA0501 # 08 Y:2013 | 08 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,771 | $650 | Not Implemented |
IA0501 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,367 | $1,800 | Implemented |
IA0501 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,728 | $2,575 | Not Implemented |
IA0501 # 05 Y:2013 | 05 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,018 | $22,500 | Not Implemented |
IA0501 # 04 Y:2013 | 04 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $486 | $334 | Not Implemented |
IA0501 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $819 | $2,680 | Implemented |
IA0479 # 07 Y:2012 | 07 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,014 | $250 | Not Implemented |
IA0479 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $655 | $3,430 | Not Implemented |
IA0479 # 05 Y:2012 | 05 | 2012 | REPOSITION OVEN WALLS TO REDUCE HEATED SPACE | $400 | $1,030 | Not Implemented |
IA0479 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,057 | $158 | Implemented |
IA0479 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $447 | $752 | Not Implemented |
IA0479 # 02 Y:2012 | 02 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,268 | $549 | Implemented |
IA0479 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $2,675 | $2,732 | Implemented |
IA0479 # 08 Y:2012 | 08 | 2012 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $234 | $240 | Not Implemented |
WI0502 # 08 Y:2005 | 08 | 2005 | IMPROVE LUBRICATION PRACTICES | $1,579 | $1,238 | Not Implemented |
WI0502 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,670 | $520 | Not Implemented |
WI0502 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,919 | $0 | Not Implemented |
WI0502 # 05 Y:2005 | 05 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $2,699 | $0 | Not Implemented |
WI0502 # 04 Y:2005 | 04 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0502 # 03 Y:2005 | 03 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0502 # 02 Y:2005 | 02 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,177 | $9,500 | Not Implemented |
WI0502 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,862 | $27,000 | Not Implemented |