IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,181

matching recommendations
Reset
SIC 305 Hose & Belting & Gaskets & Packing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0174 # 03 Y:1985 03 1985 RECOVER WASTE HEAT FROM EQUIPMENT $1,825 $1,000 Implemented
UD0174 # 04 Y:1985 04 1985 INSULATE BARE EQUIPMENT $763 $448 Implemented
UD0174 # 05 Y:1985 05 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,290 $5,000 Not Implemented
UD0174 # 06 Y:1985 06 1985 INSTALL TIMERS AND/OR THERMOSTATS $457 $121 Implemented
OK0158 # 01 Y:1985 01 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $60 $0 Implemented
OK0158 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $161 $33 Implemented
OK0158 # 03 Y:1985 03 1985 INSTALL TIMERS AND/OR THERMOSTATS $93 $100 Not Implemented
OK0158 # 04 Y:1985 04 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $638 $180 Implemented
OK0158 # 05 Y:1985 05 1985 USE RADIANT HEATER FOR SPOT HEATING $1,375 $76 Implemented
OK0158 # 06 Y:1985 06 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,828 $3,400 Implemented
OK0163 # 01 Y:1985 01 1985 INSTALL TIMERS AND/OR THERMOSTATS $257 $360 Implemented
OK0163 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80 $138 Implemented
OK0163 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $720 $200 Implemented
OK0163 # 04 Y:1985 04 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $61 $0 Implemented
OK0163 # 05 Y:1985 05 1985 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $110 $0 Implemented
OK0163 # 06 Y:1985 06 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $258 $139 Implemented
OK0163 # 07 Y:1985 07 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $83 $78 Implemented
OK0163 # 08 Y:1985 08 1985 INSTALL SET-BACK TIMERS $83 $45 Implemented
OK0163 # 09 Y:1985 09 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $27 $190 Not Implemented
TN0220 # 01 Y:1984 01 1984 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $16,500 $29,700 Not Implemented
TN0220 # 02 Y:1984 02 1984 INSULATE BARE EQUIPMENT $35,035 $750 Implemented
TN0220 # 03 Y:1984 03 1984 USE OPTIMUM THICKNESS INSULATION $23,700 $4,570 Implemented
TN0220 # 04 Y:1984 04 1984 INSTALL SET-BACK TIMERS $18,780 $0 Not Implemented
TN0220 # 05 Y:1984 05 1984 INSULATE BARE EQUIPMENT $6,330 $400 Implemented