Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
554
matching recommendationsSIC | 3061 | Mechanical Rubber Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0292 # 06 Y:2016 | 06 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,562 | $1,832 | Not Implemented |
MI0292 # 07 Y:2016 | 07 | 2016 | USE OPTIMUM THICKNESS INSULATION | $2,670 | $1,810 | Implemented |
MI0292 # 08 Y:2016 | 08 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,585 | $670 | Not Implemented |
MI0292 # 09 Y:2016 | 09 | 2016 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,313 | $480 | Not Implemented |
MI0292 # 10 Y:2016 | 10 | 2016 | USE PHOTOCELL CONTROLS | $183 | $480 | Implemented |
UD0896 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $74 | $0 | Implemented |
UD0896 # 02 Y:2014 | 02 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $31,308 | $10,500 | Not Implemented |
UD0896 # 03 Y:2014 | 03 | 2014 | MINIMIZE WATER USAGE | $7,067 | $8,000 | Not Implemented |
UD0896 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $500 | Not Implemented |
UD0896 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22 | $0 | Not Implemented |
UD0896 # 06 Y:2014 | 06 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $8,000 | Not Implemented |
UD0896 # 07 Y:2014 | 07 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,035 | $1,211 | Not Implemented |
UD0896 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $794 | $1,000 | Not Implemented |
WV0477 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $3,015 | $2,013 | Implemented |
WV0477 # 02 Y:2013 | 02 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,823 | $6,345 | Not Implemented |
WV0477 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,064 | $3,573 | Not Implemented |
WV0477 # 04 Y:2013 | 04 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,996 | $1,000 | Not Implemented |
WV0477 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $1,581 | Not Implemented |
WV0477 # 06 Y:2013 | 06 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $595 | $257 | Implemented |
WV0477 # 07 Y:2013 | 07 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $490 | $1,035 | Implemented |
WV0477 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $366 | $135 | Implemented |
WV0477 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $260 | $137 | Implemented |
WV0477 # 10 Y:2013 | 10 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $257 | $586 | Not Implemented |
UK1316 # 01 Y:2013 | 01 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $21,600 | $0 | Implemented |
UK1316 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,113 | $0 | Not Implemented |