Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
387
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0381 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $900 | $2,470 | Not Implemented |
GT0381 # 04 Y:1989 | 04 | 1989 | AIR CONDITION ONLY SPACE NECESSARY | $2,469 | $420 | Not Implemented |
GT0355 # 01 Y:1988 | 01 | 1988 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,437 | $7,830 | Not Implemented |
GT0355 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $535 | $300 | Implemented |
GT0355 # 03 Y:1988 | 03 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $702 | $85 | Implemented |
GT0355 # 04 Y:1988 | 04 | 1988 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $136 | $140 | Not Implemented |
GT0355 # 05 Y:1988 | 05 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $11,594 | $25,480 | Implemented |
GT0344 # 01 Y:1988 | 01 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $37,911 | $21,000 | Not Implemented |
GT0344 # 02 Y:1988 | 02 | 1988 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,970 | $2,830 | Not Implemented |
GT0344 # 03 Y:1988 | 03 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,230 | $2,600 | Not Implemented |
GT0344 # 04 Y:1988 | 04 | 1988 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $90 | $35 | Not Implemented |
GT0344 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $140 | $0 | Not Implemented |
GT0344 # 06 Y:1988 | 06 | 1988 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $7,280 | $1,200 | Not Implemented |
GT0344 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,772 | $8,751 | Not Implemented |
GT0344 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $725 | $5,250 | Not Implemented |
GT0351 # 01 Y:1988 | 01 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $600 | $0 | Not Implemented |
GT0351 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $373 | $2,000 | Not Implemented |
GT0351 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36 | $25 | Not Implemented |
GT0351 # 04 Y:1988 | 04 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $920 | $540 | Not Implemented |
GT0351 # 05 Y:1988 | 05 | 1988 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,560 | $4,190 | Not Implemented |
GT0351 # 06 Y:1988 | 06 | 1988 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $690 | $300 | Not Implemented |
GT0340 # 01 Y:1988 | 01 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,410 | $1,640 | Implemented |
GT0340 # 02 Y:1988 | 02 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,580 | $1,000 | Implemented |
GT0340 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $320 | $160 | Implemented |
GT0340 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,790 | $12,930 | Not Implemented |