Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

298

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0471 # 03 Y:2019 03 2019 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $24,476 $20,000 Implemented
LE0471 # 04 Y:2019 04 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $26,397 $30,000 Implemented
LE0471 # 01 Y:2019 01 2019 INSTALL TIMERS AND/OR THERMOSTATS $666 $35 Not Implemented
LE0471 # 05 Y:2019 05 2019 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $6,634 $18,400 Implemented
LE0471 # 06 Y:2019 06 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $854 $3,225 Implemented
LE0440 # 10 Y:2017 10 2017 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $14,063 $56,424 Implemented
LE0440 # 06 Y:2017 06 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $128,735 $65,000 Not Implemented
LE0440 # 11 Y:2017 11 2017 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $4,060 $20,000 Implemented
LE0440 # 09 Y:2017 09 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,392 $38,954 Implemented
LE0440 # 08 Y:2017 08 2017 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $86,307 $68,000 Implemented
LE0440 # 05 Y:2017 05 2017 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $55,847 $28,000 Not Implemented
LE0440 # 03 Y:2017 03 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $21,749 $3,000 Implemented
LE0440 # 02 Y:2017 02 2017 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $97,167 $5,000 Implemented
LE0440 # 07 Y:2017 07 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $40,410 $26,250 Not Implemented
LE0440 # 01 Y:2017 01 2017 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $14,163 $17 Implemented
LE0440 # 04 Y:2017 04 2017 RECOVER WASTE HEAT FROM EQUIPMENT $41,418 $13,000 Implemented
DL0145 # 03 Y:2015 03 2015 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $3,810 $700 Not Implemented
DL0145 # 04 Y:2015 04 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $14,618 $30,804 Not Implemented
DL0145 # 05 Y:2015 05 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,334 $9,600 Not Implemented
DL0145 # 06 Y:2015 06 2015 INSTALL SET-BACK TIMERS $6,174 $2,500 Not Implemented
DL0145 # 07 Y:2015 07 2015 INSTALL TIMERS AND/OR THERMOSTATS $3,560 $300 Implemented
DL0145 # 08 Y:2015 08 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,831 $40,000 Implemented
DL0145 # 09 Y:2015 09 2015 RECOVER WASTE HEAT FROM EQUIPMENT $17,074 $64,980 Not Implemented
DL0145 # 02 Y:2015 02 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,440 $0 Implemented
DL0145 # 01 Y:2015 01 2015 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $48,766 $10,000 Not Implemented