Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
896
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0063 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,436 | $3,360 | Implemented |
KG0063 # 02 Y:1996 | 02 | 1996 | REDUCE VENTILATION AIR | $3,755 | $0 | Implemented |
KG0063 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,862 | $9,220 | Not Implemented |
KG0063 # 04 Y:1996 | 04 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $294 | $300 | Implemented |
KG0063 # 05 Y:1996 | 05 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $143 | $400 | Not Implemented |
KG0063 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,419 | $600 | Not Implemented |
KG0063 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,948 | $1,507 | Implemented |
KG0063 # 08 Y:1996 | 08 | 1996 | ISOLATE HOT OR COLD EQUIPMENT | $5,283 | $300 | Implemented |
KG0063 # 09 Y:1996 | 09 | 1996 | USE OPTIMUM TEMPERATURE | $3,805 | $0 | Implemented |
KG0063 # 10 Y:1996 | 10 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $11,613 | $0 | Implemented |
KG0063 # 11 Y:1996 | 11 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $557,549 | $5,000 | Not Implemented |
AM0277 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $351,900 | $70,000 | Not Implemented |
AM0277 # 02 Y:1996 | 02 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $34,050 | $30,000 | Implemented |
AM0277 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $28,650 | $180 | Implemented |
AM0277 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $22,800 | $25,000 | Not Implemented |
AM0277 # 05 Y:1996 | 05 | 1996 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,300 | $0 | Not Implemented |
AM0277 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,420 | $4,410 | Implemented |
AM0277 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $1,600 | $2,500 | Implemented |
AM0277 # 08 Y:1996 | 08 | 1996 | INSULATE BARE EQUIPMENT | $1,250 | $50 | Not Implemented |
AM0277 # 09 Y:1996 | 09 | 1996 | INSULATE BARE EQUIPMENT | $880 | $50 | Not Implemented |
AM0277 # 10 Y:1996 | 10 | 1996 | INSULATE BARE EQUIPMENT | $860 | $860 | Not Implemented |
AM0277 # 11 Y:1996 | 11 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $530 | $120 | Implemented |
AM0273 # 01 Y:1996 | 01 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $167,000 | $73,600 | Implemented |
AM0273 # 02 Y:1996 | 02 | 1996 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $7,330 | $400 | Implemented |
AM0273 # 03 Y:1996 | 03 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,830 | $0 | Not Implemented |