Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

194

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0101 # 01 Y:1998 01 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $166 $200 Implemented
NV0101 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $87 $74 Implemented
NV0101 # 03 Y:1998 03 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $234 $50 Not Implemented
NV0101 # 04 Y:1998 04 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $341 $600 Implemented
NV0101 # 05 Y:1998 05 1998 INSULATE BARE EQUIPMENT $337 $255 Not Implemented
NV0101 # 06 Y:1998 06 1998 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $51,111 $60,000 Not Implemented
NV0101 # 07 Y:1998 07 1998 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $16,500 $66,275 Implemented
NV0100 # 01 Y:1998 01 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $917 $150 Implemented
NV0100 # 02 Y:1998 02 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $233 $326 Implemented
NV0100 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,558 $1,890 Not Implemented
NV0100 # 04 Y:1998 04 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $443 $135 Implemented
NV0100 # 05 Y:1998 05 1998 USE PHOTOCELL CONTROLS $2,667 $495 Implemented
NV0100 # 06 Y:1998 06 1998 UTILIZE OUTSIDE CONTRACTING $42,320 $25,000 Not Implemented
NV0092 # 01 Y:1997 01 1997 INSTALL OCCUPANCY SENSORS $712 $246 Not Implemented
NV0092 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $291 $21 Implemented
NV0092 # 03 Y:1997 03 1997 OPTIMIZE PLANT POWER FACTOR $4,820 $24,919 Not Implemented
NV0092 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $629 $4,180 Implemented
NV0092 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $769 $200 Implemented
NV0092 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,147 $60 Implemented
NV0092 # 07 Y:1997 07 1997 INSULATE BARE EQUIPMENT $6,347 $716 Implemented
NV0092 # 08 Y:1997 08 1997 INSULATE BARE EQUIPMENT $1,493 $566 Not Implemented
NV0092 # 09 Y:1997 09 1997 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $200 $120 Not Implemented
NV0089 # 01 Y:1997 01 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,737 $650 n/a
NV0089 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $752 $246 n/a
NV0089 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,686 $946 n/a