Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
932
matching recommendationsSIC | 3081 | Unsupported Plastics Film & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0354 # 05 Y:2007 | 05 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,489 | $1,000 | Implemented |
WV0354 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,520 | $15,381 | Not Implemented |
WV0354 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,629 | $0 | Implemented |
WV0354 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,596 | $32 | Implemented |
WV0354 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,776 | $0 | Implemented |
WV0354 # 09 Y:2007 | 09 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,465 | $1,032 | Not Implemented |
WV0354 # 10 Y:2007 | 10 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,332 | $186 | Not Implemented |
WV0354 # 11 Y:2007 | 11 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $1,190 | $408 | Implemented |
WV0354 # 12 Y:2007 | 12 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,070 | $1,044 | Not Implemented |
WV0354 # 13 Y:2007 | 13 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $857 | $504 | Implemented |
WV0354 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $46,761 | $33,200 | Not Implemented |
WV0354 # 02 Y:2007 | 02 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,205 | $2,100 | Not Implemented |
WV0354 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,128 | $900 | Implemented |
LL0267 # 01 Y:2007 | 01 | 2007 | INSULATE BARE EQUIPMENT | $23,653 | $3,315 | Implemented |
LL0267 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,665 | $30 | Not Implemented |
LL0267 # 03 Y:2007 | 03 | 2007 | USE PHOTOCELL CONTROLS | $3,379 | $360 | Not Implemented |
LL0267 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,794 | $1,280 | Implemented |
LL0267 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $553 | $180 | Not Implemented |
LL0267 # 06 Y:2007 | 06 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $155 | $319 | Not Implemented |
LL0267 # 07 Y:2007 | 07 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $142 | $303 | Not Implemented |
LL0267 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $180 | $140 | Not Implemented |
LL0267 # 09 Y:2007 | 09 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,060 | $2,034 | Not Implemented |
MA0592 # 01 Y:2006 | 01 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $74,191 | $368,500 | Not Implemented |
MA0592 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,494 | $73,748 | Implemented |
MA0592 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,861 | $138,775 | Not Implemented |