Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

932

matching recommendations
Reset
SIC 3081 Unsupported Plastics Film & Sheet
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0054 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,084 $0 Implemented
RU0054 # 04 Y:1989 04 1989 IMPROVE LUBRICATION PRACTICES $1,897 $800 Not Implemented
RU0054 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,240 $0 Not Implemented
RU0054 # 06 Y:1989 06 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,711 $8,300 Implemented
RU0054 # 07 Y:1989 07 1989 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,481 $9,000 Not Implemented
MA0142 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $16,859 $570 Implemented
MA0142 # 02 Y:1989 02 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $39,982 $5,700 Not Implemented
MA0142 # 03 Y:1989 03 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $42,075 $45,870 Not Implemented
MA0142 # 04 Y:1989 04 1989 INSTALL SET-BACK TIMERS $6,809 $900 Not Implemented
MA0142 # 05 Y:1989 05 1989 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $43,200 $381,000 Not Implemented
MA0142 # 06 Y:1989 06 1989 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $27,100 $13,000 Implemented
MA0142 # 07 Y:1989 07 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $52,700 $680 Implemented
RU0035 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,016 $400 Implemented
RU0035 # 02 Y:1988 02 1988 IMPROVE LUBRICATION PRACTICES $3,797 $1,600 Not Implemented
RU0035 # 03 Y:1988 03 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,084 $2,520 Not Implemented
RU0035 # 04 Y:1988 04 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,825 $2,500 Implemented
RU0035 # 05 Y:1988 05 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $35,120 $25,000 Not Implemented
LT0117 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $87 Not Implemented
LT0117 # 02 Y:1988 02 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $324 $0 Implemented
LT0117 # 03 Y:1988 03 1988 INSULATE BARE EQUIPMENT $13,020 $2,700 Not Implemented
LT0117 # 04 Y:1988 04 1988 INSTALL TIMERS AND/OR THERMOSTATS $720 $330 Not Implemented
MA0112 # 01 Y:1988 01 1988 RECOVER WASTE HEAT FROM EQUIPMENT $14,021 $8,866 Not Implemented
MA0112 # 02 Y:1988 02 1988 INSTALL SET-BACK TIMERS $534 $0 Implemented
MA0112 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,210 $243 Not Implemented
MA0112 # 04 Y:1988 04 1988 REDESIGN PROCESS $5,082 $0 Not Implemented