Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

12

matching recommendations
Reset
SIC 3082 Unsupported Plastics Profile Shapes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0304 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,847 $866 Implemented
IA0304 # 02 Y:2002 02 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,497 $100 Not Implemented
IA0304 # 03 Y:2002 03 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $114 $17 Implemented
IA0304 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $532 $400 Not Implemented
IA0304 # 05 Y:2002 05 2002 RECOVER WASTE HEAT FROM EQUIPMENT $975 $1,200 Not Implemented
IA0304 # 06 Y:2002 06 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,617 $0 Not Implemented
IA0304 # 07 Y:2002 07 2002 INSTALL OCCUPANCY SENSORS $309 $600 Not Implemented
IA0304 # 08 Y:2002 08 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,112 $11,834 Implemented
IA0304 # 09 Y:2002 09 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,426 $0 Implemented
IA0304 # 10 Y:2002 10 2002 INSTALL SET-BACK TIMERS $101 $197 Implemented
IA0304 # 11 Y:2002 11 2002 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,904 $4,000 Not Implemented
IA0304 # 12 Y:2002 12 2002 INSULATE BARE EQUIPMENT $85 $180 Implemented