Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
399
matching recommendationsSIC | 3083 | Laminated Plastics Plate & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0048 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $3,841 | $1,600 | Not Implemented |
SD0048 # 05 Y:1993 | 05 | 1993 | INSTALL SET-BACK TIMERS | $4,596 | $5,840 | Implemented |
SD0048 # 04 Y:1993 | 04 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $18,758 | $17,100 | Implemented |
SD0048 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,491 | $0 | Not Implemented |
SD0048 # 02 Y:1993 | 02 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $82,299 | $143,700 | Not Implemented |
SD0048 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,294 | $1,103 | Implemented |
SD0042 # 09 Y:1993 | 09 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $10,717 | $11,800 | Not Implemented |
SD0042 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,457 | $0 | Implemented |
SD0042 # 07 Y:1993 | 07 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $803 | $650 | Implemented |
SD0042 # 06 Y:1993 | 06 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $40 | $39 | Implemented |
SD0042 # 05 Y:1993 | 05 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,580 | $0 | Not Implemented |
SD0042 # 04 Y:1993 | 04 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,264 | $10,000 | Not Implemented |
SD0042 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,759 | $20 | Implemented |
SD0042 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,484 | $1,484 | Not Implemented |
SD0042 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,753 | $2,420 | Implemented |
SD0042 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $718 | $925 | Implemented |
HO0015 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $926 | $2,367 | Not Implemented |
HO0015 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,577 | $220 | Not Implemented |
HO0015 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $569 | $220 | Not Implemented |
HO0015 # 04 Y:1992 | 04 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,732 | $1,200 | Not Implemented |
HO0015 # 05 Y:1992 | 05 | 1992 | INSULATE BARE EQUIPMENT | $597 | $183 | Not Implemented |
HO0015 # 06 Y:1992 | 06 | 1992 | REDUCE VENTILATION AIR | $8,676 | $4,850 | Not Implemented |
HO0015 # 07 Y:1992 | 07 | 1992 | INSTALL STORM WINDOWS AND DOORS | $246 | $212 | Not Implemented |
UD0346 # 05 Y:1991 | 05 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,053 | $0 | Implemented |
UD0346 # 03 Y:1991 | 03 | 1991 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,769 | $0 | Implemented |