Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
399
matching recommendationsSIC | 3083 | Laminated Plastics Plate & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0346 # 02 Y:1991 | 02 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,995 | $0 | Implemented |
UD0346 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $7,193 | $5,000 | Implemented |
UD0346 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,106 | $5,000 | Implemented |
UD0334 # 03 Y:1991 | 03 | 1991 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $5,208 | $0 | Implemented |
UD0334 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,627 | $4,000 | Implemented |
UD0334 # 01 Y:1991 | 01 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,567 | $0 | Implemented |
TN0380 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,869 | $440 | Not Implemented |
TN0380 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $6,151 | $6,350 | Not Implemented |
TN0380 # 01 Y:1989 | 01 | 1989 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $67,651 | $61,200 | Implemented |
TN0380 # 02 Y:1989 | 02 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $4,181 | $75 | Implemented |
TN0380 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,143 | $6,750 | Implemented |
TN0380 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,910 | $420 | Implemented |
MA0163 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,444 | $285 | Implemented |
MA0163 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,427 | $0 | Implemented |
MA0163 # 03 Y:1989 | 03 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,670 | $0 | Not Implemented |
MA0163 # 04 Y:1989 | 04 | 1989 | OPTIMIZE PLANT POWER FACTOR | $9,247 | $7,253 | Not Implemented |
MA0163 # 05 Y:1989 | 05 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,890 | $4,255 | Not Implemented |
MA0163 # 06 Y:1989 | 06 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,603 | $13,662 | Not Implemented |
OK0291 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $668 | Implemented |
OK0291 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,376 | $18,000 | Not Implemented |
OK0291 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $973 | $909 | Implemented |
OK0291 # 04 Y:1989 | 04 | 1989 | IMPROVE LUBRICATION PRACTICES | $4,974 | $0 | Implemented |
OK0291 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $356 | $480 | Not Implemented |
OK0291 # 06 Y:1989 | 06 | 1989 | INSTALL TURBULATORS | $1,310 | $2,450 | Not Implemented |
OK0291 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $844 | $1,500 | Implemented |