Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

338

matching recommendations
Reset
SIC 3084 Plastics Pipe
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0249 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $240 $334 Implemented
SU0249 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,727 $589 Implemented
SU0249 # 04 Y:2007 04 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,685 $289 Implemented
SU0249 # 03 Y:2007 03 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,329 $0 Implemented
SU0249 # 02 Y:2007 02 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,594 $0 Implemented
LL0206 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $28,231 $3,647 Implemented
LL0206 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,510 $8,280 Implemented
LL0206 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,379 $30 Implemented
LL0206 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $620 $525 Implemented
LL0206 # 07 Y:2004 07 2004 USE PHOTOCELL CONTROLS $323 $90 Implemented
LL0206 # 08 Y:2004 08 2004 INSTALL OCCUPANCY SENSORS $160 $150 Implemented
LL0206 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN WATER LINES AND VALVES $181 $150 Implemented
LL0206 # 10 Y:2004 10 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $114,500 $4,820 Implemented
LL0206 # 11 Y:2004 11 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,830 $1,790 Implemented
MS0249 # 01 Y:2004 01 2004 OPTIMIZE PLANT POWER FACTOR $54,067 $26,100 Implemented
MS0249 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN WATER LINES AND VALVES $19,536 $250 Implemented
MS0249 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,879 $708 Implemented
MS0249 # 11 Y:2004 11 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $488 $820 Implemented
LE0166 # 05 Y:2003 05 2003 USE OPTIMUM THICKNESS INSULATION $13,043 $2,731 Implemented
AM0432 # 01 Y:2003 01 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,800 $500 Implemented
AM0432 # 02 Y:2003 02 2003 REPAIR AND ELIMINATE STEAM LEAKS $12,670 $560 Implemented
AM0432 # 03 Y:2003 03 2003 REPAIR OR REPLACE STEAM TRAPS $9,300 $940 Implemented
AM0432 # 04 Y:2003 04 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,680 $4,300 Implemented
AM0432 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,380 $500 Implemented
AM0432 # 09 Y:2003 09 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $220 $50 Implemented