Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
884
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0873 # 06 Y:2010 | 06 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,661 | $775 | Implemented |
TT0049 # 01 Y:2010 | 01 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,280 | $9,600 | Not Implemented |
TT0049 # 02 Y:2010 | 02 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $9,803 | $4,000 | Not Implemented |
TT0049 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,257 | $50 | Not Implemented |
TT0049 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $16,200 | $18,200 | Not Implemented |
TT0049 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,756 | $173,505 | Implemented |
TT0049 # 06 Y:2010 | 06 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,723 | $0 | Not Implemented |
MZ0045 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,876 | $46,050 | Implemented |
MZ0045 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,746 | $4,200 | Not Implemented |
MZ0045 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,734 | $950 | Implemented |
MZ0045 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,645 | $0 | Implemented |
MZ0045 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,660 | $0 | Implemented |
BD0352 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $53,385 | $253,134 | Not Implemented |
BD0352 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $374 | $600 | Not Implemented |
BD0352 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $699 | $700 | Not Implemented |
BD0352 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $18,734 | $6,000 | Not Implemented |
BD0352 # 05 Y:2008 | 05 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,592 | $20,350 | Not Implemented |
BD0352 # 06 Y:2008 | 06 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $2,435 | $3,180 | Not Implemented |
BD0352 # 07 Y:2008 | 07 | 2008 | MODIFY STARTUP/SHUTDOWN TIMES | $11,838 | $18,000 | Not Implemented |
MZ0017 # 01 Y:2008 | 01 | 2008 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $8,697 | $1,600 | Implemented |
MZ0017 # 02 Y:2008 | 02 | 2008 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $9,270 | $175 | Not Implemented |
MZ0017 # 03 Y:2008 | 03 | 2008 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $13,980 | $15,763 | Implemented |
UD0756 # 01 Y:2007 | 01 | 2007 | USE POWER DURING OFF-PEAK PERIODS | $58,368 | $0 | Implemented |
UD0756 # 02 Y:2007 | 02 | 2007 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $54,790 | $0 | Implemented |
UD0756 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,822 | $18,000 | Implemented |