Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
884
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0189 # 02 Y:2000 | 02 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,448 | $0 | Not Implemented |
WV0189 # 03 Y:2000 | 03 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $728 | $780 | Not Implemented |
WV0189 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $338 | $120 | Not Implemented |
WV0189 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $498 | $325 | Implemented |
WV0189 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $675 | $275 | Implemented |
WV0189 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,574 | $32 | Not Implemented |
WV0189 # 08 Y:2000 | 08 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,653 | $10,800 | Implemented |
WV0189 # 09 Y:2000 | 09 | 2000 | INSTALL SKYLIGHTS | $2,123 | $2,436 | Implemented |
WV0189 # 10 Y:2000 | 10 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $120 | $25 | Not Implemented |
WV0189 # 11 Y:2000 | 11 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $887 | $5,000 | Not Implemented |
WV0189 # 12 Y:2000 | 12 | 2000 | INSTALL BACK-UP EQUIPMENT | $13,104 | $375 | Implemented |
GT0685 # 01 Y:2000 | 01 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,280 | $0 | Implemented |
GT0685 # 02 Y:2000 | 02 | 2000 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $13,650 | $11,650 | Implemented |
GT0685 # 03 Y:2000 | 03 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $714 | $500 | Implemented |
GT0685 # 04 Y:2000 | 04 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $28,840 | $7,000 | Implemented |
GT0685 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,955 | $0 | Implemented |
GT0685 # 06 Y:2000 | 06 | 2000 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $93,536 | $30,000 | Not Implemented |
GT0685 # 07 Y:2000 | 07 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $144,500 | $150,000 | Not Implemented |
GT0685 # 08 Y:2000 | 08 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $14,950 | $4,740 | Not Implemented |
UF0232 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $192,386 | $82,242 | Not Implemented |
UF0232 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,006 | $60 | Implemented |
UF0232 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,521 | $1,500 | Implemented |
UF0232 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,539 | $834 | Implemented |
UF0232 # 05 Y:1999 | 05 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,215 | $0 | Implemented |