Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
429
matching recommendationsSIC | 3086 | Plastics Foam Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0009 # 02 Y:1991 | 02 | 1991 | OPTIMIZE PLANT POWER FACTOR | $4,932 | $2,835 | Implemented |
ND0009 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $971 | $0 | Implemented |
ND0009 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $420 | $0 | Implemented |
ND0009 # 05 Y:1991 | 05 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $470 | $200 | Implemented |
OK0329 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $57 | Implemented |
OK0329 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $1,671 | $0 | Implemented |
OK0329 # 04 Y:1990 | 04 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $290 | $0 | Implemented |
OK0329 # 05 Y:1990 | 05 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,363 | $450 | Implemented |
WI0091 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $883 | $352 | Implemented |
WI0091 # 04 Y:1990 | 04 | 1990 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $579 | $0 | Implemented |
AM0086 # 01 Y:1990 | 01 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,920 | $50,000 | Implemented |
AM0086 # 02 Y:1990 | 02 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,910 | $3,880 | Implemented |
AM0086 # 03 Y:1990 | 03 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $2,700 | $800 | Implemented |
AM0086 # 04 Y:1990 | 04 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,570 | $1,000 | Implemented |
AM0086 # 05 Y:1990 | 05 | 1990 | IMPROVE LUBRICATION PRACTICES | $1,530 | $3,000 | Implemented |
AM0086 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $176 | $257 | Implemented |
AM0086 # 08 Y:1990 | 08 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $318 | $0 | Implemented |
AM0086 # 09 Y:1990 | 09 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $167 | $275 | Implemented |
LT0130 # 01 Y:1988 | 01 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $859 | $600 | Implemented |
LT0130 # 03 Y:1988 | 03 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,270 | $0 | Implemented |
LT0130 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,810 | $0 | Implemented |
LT0130 # 07 Y:1988 | 07 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $590 | $300 | Implemented |
RU0040 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,115 | $412 | Implemented |
RU0040 # 02 Y:1988 | 02 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,463 | $0 | Implemented |
RU0040 # 05 Y:1988 | 05 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,098 | $0 | Implemented |