Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,860
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0176 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $428 | $650 | Implemented |
OK0176 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45 | $12 | Implemented |
OK0176 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $191 | $240 | Implemented |
OK0176 # 04 Y:1985 | 04 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $71 | $145 | Implemented |
OK0176 # 05 Y:1985 | 05 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18 | $60 | Implemented |
CO0022 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,005 | $812 | Implemented |
CO0022 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $235 | $300 | Implemented |
CO0022 # 05 Y:1985 | 05 | 1985 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $111 | $100 | Implemented |
CO0022 # 06 Y:1985 | 06 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,775 | $100 | Implemented |
CO0022 # 08 Y:1985 | 08 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $898 | $100 | Implemented |
CO0022 # 09 Y:1985 | 09 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $253 | $12 | Implemented |
CO0022 # 10 Y:1985 | 10 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $77 | $0 | Implemented |
TN0239 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,129 | $180 | Implemented |
TN0239 # 02 Y:1985 | 02 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,382 | $0 | Implemented |
TN0239 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,463 | $75 | Implemented |
TN0239 # 04 Y:1985 | 04 | 1985 | INSTALL SET-BACK TIMERS | $488 | $0 | Implemented |
UD0151 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $1,349 | $315 | Implemented |
ST0019 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,367 | $1,116 | Implemented |
ST0019 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,428 | $56 | Implemented |
ST0019 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $691 | $300 | Implemented |
ST0019 # 05 Y:1985 | 05 | 1985 | USE OPTIMUM THICKNESS INSULATION | $541 | $240 | Implemented |
ST0019 # 06 Y:1985 | 06 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $666 | $150 | Implemented |
ST0019 # 08 Y:1985 | 08 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,350 | $0 | Implemented |
ST0019 # 09 Y:1985 | 09 | 1985 | USE COMPRESSOR AIR FILTERS | $148 | $40 | Implemented |
ST0019 # 10 Y:1985 | 10 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $274 | $500 | Implemented |