Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
217
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0964 # 08 Y:2017 | 08 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,602 | $7,700 | Not Implemented |
OK0964 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $246 | $800 | Not Implemented |
OK0964 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,682 | $38,281 | Implemented |
OK0964 # 09 Y:2017 | 09 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $8,883 | $1,250 | Not Implemented |
OK0964 # 11 Y:2017 | 11 | 2017 | INSTALL SET-BACK TIMERS | $5,720 | $4,750 | Not Implemented |
OK0883 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $7,584 | $15,000 | Not Implemented |
OK0883 # 12 Y:2014 | 12 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $23,778 | $19,100 | Not Implemented |
OK0883 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $221 | $1,083 | Not Implemented |
OK0883 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,972 | $1,750 | Not Implemented |
OK0883 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $445 | $2,048 | Not Implemented |
OK0883 # 07 Y:2014 | 07 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $4,226 | $2,681 | Not Implemented |
OK0883 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $925 | $1,510 | Implemented |
OK0883 # 10 Y:2014 | 10 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,481 | $30,000 | Not Implemented |
OK0883 # 09 Y:2014 | 09 | 2014 | OPTIMIZE PLANT POWER FACTOR | $8,198 | $18,876 | Not Implemented |
OK0883 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $906 | $463 | Not Implemented |
OK0883 # 06 Y:2014 | 06 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,030 | $980 | Implemented |
OK0883 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $2,502 | $2,480 | Not Implemented |
OK0882 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $2,940 | Not Implemented |
OK0882 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $8,378 | $2,870 | Not Implemented |
OK0882 # 11 Y:2014 | 11 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $5,834 | $6,336 | Not Implemented |
OK0882 # 09 Y:2014 | 09 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,908 | $1,113 | Not Implemented |
OK0882 # 04 Y:2014 | 04 | 2014 | INSTALL SET-BACK TIMERS | $142 | $170 | Not Implemented |
OK0882 # 10 Y:2014 | 10 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $333 | $0 | Implemented |
OK0882 # 05 Y:2014 | 05 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,361 | $28 | Not Implemented |
OK0882 # 02 Y:2014 | 02 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $37,574 | $29,200 | Not Implemented |