Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0229 # 04 Y:2012 04 2012 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $21,533 $46,296 Not Implemented
MI0229 # 13 Y:2012 13 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $624 $1,852 Implemented
MI0229 # 12 Y:2012 12 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,297 $460 Implemented
MI0229 # 11 Y:2012 11 2012 INSTALL SKYLIGHTS $2,117 $3,000 Implemented
MI0229 # 10 Y:2012 10 2012 INSTALL OCCUPANCY SENSORS $2,325 $480 Implemented
MI0229 # 09 Y:2012 09 2012 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $5,382 $385 Implemented
MI0229 # 08 Y:2012 08 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,849 $80 Implemented
MI0229 # 07 Y:2012 07 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,865 $1,660 Implemented
MI0229 # 06 Y:2012 06 2012 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $14,915 $80 Implemented
MI0229 # 05 Y:2012 05 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $15,948 $7,160 Not Implemented
MI0229 # 03 Y:2012 03 2012 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $26,164 $22,464 Implemented
MI0229 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $39,024 $168,378 Not Implemented
MI0229 # 01 Y:2012 01 2012 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $69,199 $111,000 Implemented
MI0216 # 01 Y:2012 01 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $7,554 $8,000 Implemented
MI0216 # 06 Y:2012 06 2012 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $853 $3,656 Implemented
MI0216 # 05 Y:2012 05 2012 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,128 $500 Implemented
MI0216 # 04 Y:2012 04 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,170 $1,320 Implemented
MI0216 # 03 Y:2012 03 2012 INSTALL / REPAIR INSULATION ON STEAM LINES $3,759 $1,592 Implemented
MI0216 # 02 Y:2012 02 2012 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $5,307 $8,856 Not Implemented