Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
315
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0013 # 09 Y:1993 | 09 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $160 | $6,080 | Implemented |
WV0013 # 10 Y:1993 | 10 | 1993 | REDUCE SCRAP PRODUCTION | $26,683 | $0 | Implemented |
WV0006 # 01 Y:1993 | 01 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $340 | $210 | Implemented |
WV0006 # 02 Y:1993 | 02 | 1993 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $11,642 | $8,490 | Implemented |
WV0006 # 03 Y:1993 | 03 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $480 | $450 | Implemented |
WV0006 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $303 | $335 | Implemented |
WV0006 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $52 | $2,300 | Implemented |
WV0006 # 06 Y:1993 | 06 | 1993 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,366 | $555 | Implemented |
WV0005 # 01 Y:1993 | 01 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $490 | $160 | Implemented |
WV0005 # 02 Y:1993 | 02 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,989 | $20 | Not Implemented |
WV0005 # 03 Y:1993 | 03 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $16,651 | $1,600 | Not Implemented |
WV0005 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $36,648 | $7,690 | Not Implemented |
WV0005 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,833 | $41,350 | Implemented |
WV0005 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,008 | $2,485 | Implemented |
WV0005 # 07 Y:1993 | 07 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $4,213 | $3,542 | Implemented |