IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 3251 Brick And Structural Clay Tile
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0067 # 04 Y:1982 04 1982 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $82,335 $19,850 Implemented
OK0067 # 13 Y:1982 13 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $508 $300 Implemented
OK0067 # 12 Y:1982 12 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $151 $94 Not Implemented
OK0067 # 11 Y:1982 11 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $325 $990 Not Implemented
OK0067 # 10 Y:1982 10 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,571 $2,970 Not Implemented
OK0067 # 09 Y:1982 09 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,881 $15,180 Not Implemented
OK0067 # 08 Y:1982 08 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $113 $91 Implemented
OK0067 # 07 Y:1982 07 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,311 $147 Implemented
OK0067 # 06 Y:1982 06 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $318 $760 Not Implemented
OK0067 # 05 Y:1982 05 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,007 $994 Not Implemented
OK0067 # 03 Y:1982 03 1982 INSULATE BARE EQUIPMENT $5,689 $2,430 Implemented
OK0067 # 02 Y:1982 02 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $63,919 $3,400 Implemented
OK0067 # 01 Y:1982 01 1982 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $13,100 $40,311 Not Implemented
GT0158 # 01 Y:1982 01 1982 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $13,543 $17,096 Not Implemented
GT0158 # 03 Y:1982 03 1982 INSULATE BARE EQUIPMENT $1,163 $448 Not Implemented
GT0158 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,305 $107 Not Implemented
OK0017 # 04 Y:1982 04 1982 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $13,455 $2,500 Not Implemented
OK0017 # 03 Y:1982 03 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $245 $3,210 Not Implemented
OK0017 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $128 $0 Not Implemented