Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

127

matching recommendations
Reset
SIC 3253 Ceramic Wall And Floor Tile
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0181 # 06 Y:2016 06 2016 RECOVER WASTE HEAT FROM EQUIPMENT $6,973 $6,000 Implemented
TT0181 # 07 Y:2016 07 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,976 $13,245 Implemented
TT0181 # 08 Y:2016 08 2016 RECOVER WASTE HEAT FROM EQUIPMENT $3,794 $500 Not Implemented
TT0181 # 09 Y:2016 09 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,058 $3,050 Implemented
TT0181 # 10 Y:2016 10 2016 OPTIMIZE PLANT POWER FACTOR $3,012 $8,000 Implemented
UA0152 # 01 Y:2015 01 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $276,882 $132,605 Not Implemented
UA0152 # 02 Y:2015 02 2015 USE PHOTOCELL CONTROLS $1,325 $905 Implemented
UA0152 # 03 Y:2015 03 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,331 $3,245 Implemented
UA0152 # 04 Y:2015 04 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $23,335 $800 Not Implemented
UA0152 # 05 Y:2015 05 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,638 $4,800 Not Implemented
AM0579 # 01 Y:2010 01 2010 $1,058,450 $0 Not Implemented
AM0579 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34,370 $48,100 Not Implemented
AM0579 # 03 Y:2010 03 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,100 $0 Not Implemented
AM0579 # 04 Y:2010 04 2010 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $14,800 $2,500 Not Implemented
AM0579 # 05 Y:2010 05 2010 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $12,300 $2,500 Not Implemented
AM0579 # 06 Y:2010 06 2010 $1,700,000 $0 Not Implemented
AM0579 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,550 $1,000 Not Implemented
AM0579 # 08 Y:2010 08 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,415 $500 Not Implemented
AM0579 # 09 Y:2010 09 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,140 $12,387 Not Implemented
AM0579 # 10 Y:2010 10 2010 USE SYNTHETIC LUBRICANT $1,960 $0 Not Implemented
AM0579 # 11 Y:2010 11 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,320 $900 Not Implemented
OR0526 # 01 Y:2007 01 2007 $371,000 $1,113,000 Not Implemented
OR0526 # 02 Y:2007 02 2007 $162,000 $23,000 Not Implemented
OR0526 # 03 Y:2007 03 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $70,000 $48,000 Not Implemented
OR0526 # 04 Y:2007 04 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $18,200 $30,000 Implemented