Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
SIC 3271 Concrete Block And Brick
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0436 # 05 Y:1999 05 1999 $19,090 $75,000 Not Implemented
CO0436 # 04 Y:1999 04 1999 $31,100 $0 Implemented
CO0436 # 03 Y:1999 03 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $5,460 $0 Implemented
CO0436 # 02 Y:1999 02 1999 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $180 $800 Not Implemented
CO0436 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $141 $566 Implemented
CO0103 # 06 Y:1987 06 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,976 $5,729 Not Implemented
CO0103 # 05 Y:1987 05 1987 INSTALL TIMERS AND/OR THERMOSTATS $1,774 $2,100 Not Implemented
CO0103 # 04 Y:1987 04 1987 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,705 $6,000 Not Implemented
CO0103 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $616 $1,100 Not Implemented
CO0103 # 02 Y:1987 02 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,154 $0 Implemented
CO0103 # 01 Y:1987 01 1987 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $324 $50 Implemented
CO0043 # 12 Y:1985 12 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $686 $564 Implemented
CO0043 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,067 $275 Implemented
CO0043 # 11 Y:1985 11 1985 ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE $1,358 $100 Implemented
CO0043 # 10 Y:1985 10 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,316 $50 Not Implemented
CO0043 # 09 Y:1985 09 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $178 $50 Not Implemented
CO0043 # 08 Y:1985 08 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $297 $295 Implemented
CO0043 # 07 Y:1985 07 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $512 $1,799 Implemented
CO0043 # 06 Y:1985 06 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,663 $1,620 Implemented
CO0043 # 05 Y:1985 05 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $398 $150 Implemented
CO0043 # 04 Y:1985 04 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $743 $150 Implemented
CO0043 # 03 Y:1985 03 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,384 $10,000 Not Implemented
CO0043 # 02 Y:1985 02 1985 INSTALL TURBULATORS $1,154 $800 Not Implemented