IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

745

matching recommendations
Reset
SIC 3272 Concrete Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0049 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $522 $0 Not Implemented
RU0049 # 03 Y:1989 03 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $544 $0 Implemented
RU0049 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $132 $92 Implemented
RU0049 # 05 Y:1989 05 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $488 $1,125 Implemented
RU0049 # 06 Y:1989 06 1989 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $12,335 $260 Implemented
RU0049 # 07 Y:1989 07 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,434 $500 Implemented
UD0285 # 01 Y:1989 01 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,196 $700 Implemented
UD0285 # 02 Y:1989 02 1989 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,183 $2,400 Not Implemented
UD0285 # 03 Y:1989 03 1989 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,445 $400 Not Implemented
UD0285 # 04 Y:1989 04 1989 RECOVER WASTE HEAT FROM EQUIPMENT $941 $1,000 Not Implemented
UD0285 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $764 $1,005 Implemented
UD0285 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,534 $2,000 Implemented
UD0285 # 07 Y:1989 07 1989 INSTALL STORM WINDOWS AND DOORS $4,775 $2,300 Not Implemented
RU0044 # 01 Y:1988 01 1988 IMPROVE LUBRICATION PRACTICES $1,840 $800 Not Implemented
RU0044 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,908 $0 Implemented
RU0044 # 03 Y:1988 03 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $1,286 $390 Implemented
RU0044 # 04 Y:1988 04 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,369 $3,400 Not Implemented
RU0044 # 05 Y:1988 05 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,386 $0 Not Implemented
RU0044 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $456 $0 Implemented
RU0044 # 07 Y:1988 07 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $363 $500 Implemented
LT0128 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,210 $600 Implemented
LT0128 # 02 Y:1988 02 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $5,334 $2,500 Implemented
LT0128 # 03 Y:1988 03 1988 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $476 $350 Implemented
LT0128 # 04 Y:1988 04 1988 INSULATE BARE EQUIPMENT $5,670 $11,000 Not Implemented
LT0128 # 05 Y:1988 05 1988 REPAIR AND ELIMINATE STEAM LEAKS $315 $550 Implemented