Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1989
Principal Product PRESTRESSED CONCRETE
NAICS n/a
SIC 3272 - Concrete Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 69
Plant Area (Sq.Ft.) 0
Annual Production 5,000 Thousand Feet
Production Hrs. Annual 2,200
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $112,857 1,549,238 kWh $0.07
Natural Gas $95,623 23,612 MMBtu $4.05
Fuel Oil #2 $11,510 2,040 MMBtu $5.64
TOTAL ENERGY COSTS $219,990
RECOMMENDED SAVINGS* $25,054 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,494
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,196
Cost:
$700
$1,566 40,152 $(-370) (-91) - - - - $1,566
40,152
kWh
$(-370)
(-91)
MMBtu
-
-
MMBtu
-
-
$
02: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$3,183
Cost:
$2,400
$3,183 152,989 - - - - - - $3,183
152,989
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
03: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$6,445
Cost:
$400
$6,445 37,808 - - - - - - $6,445
37,808
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$941
Cost:
$1,000
- - $941 232 - - - - -
-
kWh
$941
232
MMBtu
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$764
Cost:
$1,005
$765 11,137 $(-51) (-12) - - $50 - $765
11,137
kWh
$(-51)
(-12)
MMBtu
-
-
MMBtu
$50
-
$
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,534
Cost:
$2,000
- - $4,343 1,070 $441 92 $(-250) - -
-
kWh
$4,343
1,070
MMBtu
$441
92
MMBtu
$(-250)
-
$
07: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$4,775
Cost:
$2,300
- - $4,775 1,176 - - - - -
-
kWh
$4,775
1,176
MMBtu
-
-
MMBtu
-
-
$
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,216
Cost:
$600
- - $3,216 792 - - - - -
-
kWh
$3,216
792
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$25,054
Cost:
$10,405
$11,959 242,086 $12,854 3,167 $441 92 $(-200) - $11,959
242,086
kWh
$12,854
3,167
MMBtu
$441
92
MMBtu
$(-200)
-
$
TOTAL IMPLEMENTED Savings:
$6,494
Cost:
$3,705
$2,331 51,289 $3,922 967 $441 92 $(-200) - $2,331
51,289
kWh
$3,922
967
MMBtu
$441
92
MMBtu
$(-200)
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes