Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 3273 | Ready-mixed Concrete |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0102 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $341 | $0 | Implemented |
AS0102 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $45 | $215 | Not Implemented |
AS0102 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,297 | $2,030 | Implemented |
AS0102 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,536 | $3,544 | Implemented |
AS0102 # 05 Y:1993 | 05 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,606 | $0 | Implemented |
AS0102 # 06 Y:1993 | 06 | 1993 | USE SYNTHETIC LUBRICANT | $1,145 | $300 | Not Implemented |
AS0102 # 07 Y:1993 | 07 | 1993 | INSULATE BARE EQUIPMENT | $4,374 | $4,199 | Implemented |
AS0102 # 08 Y:1993 | 08 | 1993 | INSULATE BARE EQUIPMENT | $8,447 | $1,104 | Not Implemented |
AS0102 # 09 Y:1993 | 09 | 1993 | INSULATE BARE EQUIPMENT | $4,056 | $2,513 | Not Implemented |
AS0102 # 10 Y:1993 | 10 | 1993 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $52,907 | $200,000 | Not Implemented |
AM0185 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $4,350 | $10,500 | Not Implemented |
AM0185 # 02 Y:1993 | 02 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,750 | $0 | Implemented |
AM0185 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,680 | $250 | Implemented |
AM0185 # 04 Y:1993 | 04 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,660 | $0 | Implemented |
AM0185 # 05 Y:1993 | 05 | 1993 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,160 | $320 | Not Implemented |
AM0185 # 06 Y:1993 | 06 | 1993 | USE SYNTHETIC LUBRICANT | $300 | $0 | Not Implemented |