Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
SIC 3291 Abrasive Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0105 # 08 Y:1990 08 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,002 $500 Implemented
WI0105 # 09 Y:1990 09 1990 RECOVER WASTE HEAT FROM EQUIPMENT $632 $500 Not Implemented
WI0105 # 10 Y:1990 10 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $445 $1,000 Not Implemented
WI0105 # 11 Y:1990 11 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $213 $0 Implemented
MA0088 # 01 Y:1987 01 1987 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $571 $300 Not Implemented
MA0088 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $236 $58 Not Implemented
MA0088 # 03 Y:1987 03 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $450 $0 Not Implemented
MA0088 # 04 Y:1987 04 1987 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $326 $0 Not Implemented
MA0088 # 05 Y:1987 05 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,327 $9,700 Not Implemented
UD0107 # 01 Y:1983 01 1983 INSTALL TIMERS AND/OR THERMOSTATS $1,233 $750 Not Implemented
UD0107 # 02 Y:1983 02 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,281 $487 Implemented
UD0107 # 03 Y:1983 03 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $873 $600 Not Implemented
UD0107 # 04 Y:1983 04 1983 INSTALL STORM WINDOWS AND DOORS $668 $182 Not Implemented