Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1990
Principal Product STEEL WOOL
NAICS n/a
SIC 3291 - Abrasive Products
Sales $10,000,000-$50,000,000
# of Employees 160
Plant Area (Sq.Ft.) 0
Annual Production 30,000,000 Pounds
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $265,669 3,080,305 kWh $0.09
Natural Gas $62,685 13,745 MMBtu $4.56
TOTAL ENERGY COSTS $328,354
RECOMMENDED SAVINGS* $25,774 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,948
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$10,875
Cost:
$1,250
- - $10,875 2,385 - - -
-
kWh
$10,875
2,385
MMBtu
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$3,254
Cost:
-
$3,654 - - - $(-400) - $3,654
-
kWh
-
-
MMBtu
$(-400)
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,146
Cost:
$432
$3,146 36,342 - - - - $3,146
36,342
kWh
-
-
MMBtu
-
-
$
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,696
Cost:
$1,400
$1,696 19,637 - - - - $1,696
19,637
kWh
-
-
MMBtu
-
-
$
05: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$2,224
Cost:
$4,448
- - $2,224 488 - - -
-
kWh
$2,224
488
MMBtu
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,016
Cost:
$600
- - $1,016 223 - - -
-
kWh
$1,016
223
MMBtu
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,271
Cost:
$2,032
$1,271 14,654 - - - - $1,271
14,654
kWh
-
-
MMBtu
-
-
$
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,002
Cost:
$500
- - $1,002 220 - - -
-
kWh
$1,002
220
MMBtu
-
-
$
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$632
Cost:
$500
- - $632 139 - - -
-
kWh
$632
139
MMBtu
-
-
$
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$445
Cost:
$1,000
$445 5,275 - - - - $445
5,275
kWh
-
-
MMBtu
-
-
$
11: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$213
Cost:
-
- - $213 47 - - -
-
kWh
$213
47
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$25,774
Cost:
$12,162
$10,212 75,908 $15,962 3,502 $(-400) - $10,212
75,908
kWh
$15,962
3,502
MMBtu
$(-400)
-
$
TOTAL IMPLEMENTED Savings:
$17,948
Cost:
$4,182
$4,842 55,979 $13,106 2,875 - - $4,842
55,979
kWh
$13,106
2,875
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes