Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 3291 | Abrasive Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0190 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,345 | $1,020 | Implemented |
MI0190 # 02 Y:2010 | 02 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,171 | $2,804 | Not Implemented |
MI0190 # 03 Y:2010 | 03 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,721 | $2,507 | Implemented |
MI0190 # 04 Y:2010 | 04 | 2010 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,587 | $700 | Not Implemented |
MI0190 # 05 Y:2010 | 05 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,758 | $4,871 | Not Implemented |
UF0254 # 01 Y:2000 | 01 | 2000 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $288,146 | $1,200,000 | Not Implemented |
UF0254 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $140,156 | $26,813 | Implemented |
UF0254 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,374 | $3,223 | Implemented |
UF0254 # 04 Y:2000 | 04 | 2000 | INSULATE BARE EQUIPMENT | $8,849 | $2,975 | Implemented |
UF0254 # 05 Y:2000 | 05 | 2000 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,420 | $1,212 | Implemented |
UF0254 # 06 Y:2000 | 06 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,529 | $50 | Implemented |
UF0254 # 07 Y:2000 | 07 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $73,125 | $100,000 | Not Implemented |
UF0254 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $32,500 | $22,020 | Not Implemented |
UF0254 # 09 Y:2000 | 09 | 2000 | INSTALL SENSORS TO DETECT DEFECTS | $53,501 | $5,465 | Not Implemented |
UF0254 # 10 Y:2000 | 10 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $65,000 | $12,000 | Not Implemented |