Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2000 |
Principal Product | Clay and Industrial Sand |
NAICS | n/a |
SIC | 3291 - Abrasive Products |
Sales | $5,000,000-$10,000,000 |
# of Employees | 49 |
Plant Area (Sq.Ft.) | 87,000,000 |
Annual Production | 250,000 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $284,851 | 9,574,150 | kWh | $0.03 |
Electricity Demand | $160,786 | 29,347 | kW-months/year | $5.48 |
Natural Gas | $590,800 | 172,925 | MMBtu | $3.42 |
TOTAL ENERGY COSTS | $1,036,437 | |||
RECOMMENDED SAVINGS* | $673,600 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $161,328 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $288,146 Cost: $1,200,000 |
- | - | $288,146 | 1,500 | - | - | - | - | - | - |
- - kWh |
$288,146 1,500 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $140,156 Cost: $26,813 |
$54,730 | 1,765,533 | $85,426 | 5,602 | - | - | - | - | - | - |
$54,730 1,765,533 kWh |
$85,426 5,602 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,374 Cost: $3,223 |
$2,410 | 62,134 | $964 | 176 | - | - | - | - | - | - |
$2,410 62,134 kWh |
$964 176 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $8,849 Cost: $2,975 |
- | - | - | - | $8,849 | 2,590 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,849 2,590 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $1,420 Cost: $1,212 |
$1,420 | 30,188 | - | - | - | - | - | - | - | - |
$1,420 30,188 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $7,529 Cost: $50 |
- | - | - | - | - | - | - | - | $7,529 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$7,529 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $73,125 Cost: $100,000 |
- | - | - | - | - | - | $73,125 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$73,125 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $32,500 Cost: $22,020 |
- | - | - | - | - | - | $32,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$32,500 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $53,501 Cost: $5,465 |
- | - | - | - | - | - | $53,501 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$53,501 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $65,000 Cost: $12,000 |
- | - | - | - | - | - | $65,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$65,000 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $673,600 Cost: $1,373,758 |
$58,560 | 1,857,855 | $374,536 | 7,278 | $8,849 | 2,590 | $224,126 | - | $7,529 | - | $58,560 1,857,855 kWh |
$374,536 7,278 kW-months/year |
$8,849 2,590 MMBtu |
$224,126 - lb |
$7,529 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $161,328 Cost: $34,273 |
$58,560 | 1,857,855 | $86,390 | 5,778 | $8,849 | 2,590 | - | - | $7,529 | - | $58,560 1,857,855 kWh |
$86,390 5,778 kW-months/year |
$8,849 2,590 MMBtu |
- - lb |
$7,529 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |