IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,313

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0004 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,138 $7,537 Not Implemented
UM0004 # 04 Y:1994 04 1994 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $82,470 $39,200 Not Implemented
UM0004 # 05 Y:1994 05 1994 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $14,700 $3,560 Not Implemented
AM0214 # 01 Y:1994 01 1994 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $10,770 $200,000 Not Implemented
AM0214 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,160 $540 Not Implemented
AM0214 # 03 Y:1994 03 1994 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $5,350 $300 Not Implemented
AM0214 # 04 Y:1994 04 1994 USE OPTIMUM TEMPERATURE $790 $1,000 Not Implemented
AM0214 # 05 Y:1994 05 1994 ADJUST BURNERS FOR EFFICIENT OPERATION $450 $680 Implemented
AM0214 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $300 $0 Not Implemented
NC0025 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,071 $420 Implemented
NC0025 # 02 Y:1994 02 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,423 $8,000 Not Implemented
NC0025 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,042 $710 Implemented
NC0025 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,019 $13,400 Implemented
NC0025 # 05 Y:1994 05 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $317 $660 Not Implemented
NC0025 # 06 Y:1994 06 1994 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $2,797 $750 Implemented
NC0025 # 07 Y:1994 07 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,660 $2,500 Not Implemented
NC0025 # 08 Y:1994 08 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $690 $1,500 Not Implemented
TN0529 # 01 Y:1994 01 1994 COVER OPEN TANKS $8,253 $100 Implemented
TN0529 # 02 Y:1994 02 1994 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $3,332 $0 Implemented
TN0529 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $434 $450 Not Implemented
TN0529 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $234 $200 Not Implemented
TN0529 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $150 $330 Not Implemented
TN0529 # 06 Y:1994 06 1994 CONVERT TO AQUEOUS CLEANING $9,690 $36,600 Not Implemented
TN0529 # 07 Y:1994 07 1994 INSTALL SHROUDING ON MACHINES TO PREVENT SPLASHING $7,800 $344 Implemented
TN0529 # 08 Y:1994 08 1994 RECYCLE CASTING SAND $5,592 $16,000 Not Implemented